• Electrohydraulic directioanl valve directioanls the oil path by controlling the main spool
• WEH electrohydraulic control
• Installation face follow DIN 24340 A, ISO 4401 and CETOP-RP 121H Sub-plate mounting connection
• Wet DC or AC solenoid (optional)
• With manual emergency control
• Electropneumatic connection as single or center connection
• Spring or hydraulic alignment or bias
NG10
| Specifications | H-WEH10 type | WEH10 type | ||||||||
| Max. operating pressure:P、A、B | 350 | 280 | ||||||||
| Port T | With external pilot oil drain bar | 315 | ||||||||
| With internal pilot oil drain bar | DC 210 AC 160 | |||||||||
| Port Y | With external pilot oil drain bar | DC 210 AC 160 | ||||||||
| Min. control pressure | With external pilot oil supply ( not apply to C、Z、 F、G、H、P、T、V) bar | 3-position valve 10 | ||||||||
| Spring-return 2-position valve 10 | ||||||||||
| Hydraulic-return 2-position valve 7 | ||||||||||
| With internal pilot oil supply ( apply to C、Z、F、 G、H、P、T、V) bar | 6.5 | |||||||||
| Max. control pressure bar | 250 | |||||||||
| Fluid | Mineral oil,Phosphate ester | |||||||||
| Fluid temperature range ℃ | -30 to +80 ( NBR seals | |||||||||
| -20 to +80 ( FKM seals ) | ||||||||||
| Viscosity range mm2/s | 2.8 to 500 | |||||||||
| Switching pilot oil volume cm3 | 3-position valve 2.04 | |||||||||
| 2-position valve 4.08 | ||||||||||
| Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC ) | ||||||||||
| Control pressure bar | 70 | 140 | 210 | 250 | ||||||
| AC | DC | AC | DC | AC | DC | AC | DC | |||
| 3-position valve ms | 30 | 65 | 25 | 60 | 20 | 55 | 15 | 50 | ||
| 2-position valve ms | 35 | 80 | 30 | 75 | 25 | 70 | 20 | 65 | ||
| Switching times (= Valve switching time from the switched position to the neutral position) | ||||||||||
| 3-position valve ms | 30 | |||||||||
| 2-position valve ms | 35 | 40 | 30 | 35 | 25 | 30 | 20 | 25 | ||
| Installation position | HC、HD、HK、HZ、HY Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily | |||||||||
| Flow of shortest switching time L/min | about 35 | |||||||||
| Weight | Single solenoid valve kg | 6.7 | ||||||||
| Double solenoid valve kg | 7.1 | |||||||||
| Switching time regulator kg | 1.0 | |||||||||
| Reducing valve kg | 0.5 | |||||||||
NG16
| Specifications | H-...WEH16... type | ...WEH16... type | ||||||||||||
| Max. operating pressure:P、A、B | 350 | |||||||||||||
| Port T | With external pilot oil drain bar | 250 | ||||||||||||
| With internal pilot oil drain bar | DC 210 AC 160 | |||||||||||||
| Hydraulic-centering 3-position valve With internal pilot oil drain is impossible | ||||||||||||||
| Port Y | With external pilot oil drain bar | DC 210 AC 160 | ||||||||||||
| Min. control pressure | With external pilot oil supply ( not apply to C、Z、 | 3-position valve 14 | ||||||||||||
| Spring-return 2-position valve 14 | ||||||||||||||
| Hydraulic-return 2-position valve 14 | ||||||||||||||
| With internal pilot oil supply ( apply to C、Z、F、 G、 H、P、T、V) bar | When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V | |||||||||||||
| Max. control pressure bar | 250 | |||||||||||||
| Fluid | Mineral oil,Phosphate ester | |||||||||||||
| Fluid temperature range ℃ | -30 to +80 ( NBR seals | |||||||||||||
| -20 to +80 ( FKM seals ) | ||||||||||||||
| Viscosity range mm2/s | 2.8 to 500 | |||||||||||||
| Switching pilot oil volume | ||||||||||||||
| - Spring-centering 3-position valve cm3 | 5.72 | |||||||||||||
| - 2-position valve cm3 | 11.45 | |||||||||||||
| Hydraulic-centering 3-position valve | ||||||||||||||
| - From"0"position to working position"a" cm3 | 2.83 | |||||||||||||
| - From working position"a" to "0"position cm3 | 2.9 | |||||||||||||
| - From"a"position to working position"b" cm3 | 5.72 | |||||||||||||
| - From working position"b" to "0"position cm3 | 2.83 | |||||||||||||
| * * Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC) | ||||||||||||||
| Control pressure bar | 50 | 150 | 250 | |||||||||||
| AC | DC | AC | DC | AC | DC | AC | DC | AC | DC | AC | DC | |||
| - Spring-centering 3-position valve ms | 35 | 65 | 30 | 60 | 30 | 58 | ||||||||
| - 2-position valve ms | 45 | 65 | 35 | 55 | 30 | 50 | ||||||||
| - Hydraulic-centering 3-position valve ms | / | b | a | b | a | b | a | b | a | b | a | b | ||
| 30 | 65 | 25 | 55 | 63 | 20 | 25 | 55 | 60 | ||||||
| **Switching times (= Valve switching time from the neutral position to the switched position) | ||||||||||||||
| - Spring-centering 3-position valve ms | 30 | |||||||||||||
| - 2-position valve ms | 45 | 45 | 35 | 35 | 30 | 30 | ||||||||
| - Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | ||
| 20 | 20 | 20 | 20 | 20 | 20 | |||||||||
| Installation position | C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily | |||||||||||||
| Flow of shortest switching time L/min | about 35 | |||||||||||||
| Weight kg | about 9.5 | |||||||||||||
NG25
| Specifications | H-...WEH25... type | ...WEH25... type | ||||||||||||||||
| Max. operating pressure:P、A、B | 350 | 280 | ||||||||||||||||
| Port T | With external pilot oil drain bar | 250 | ||||||||||||||||
| With internal pilot oil drain bar | DC 210 AC 160 | |||||||||||||||||
| Hydraulic-centering 3-position valve With internal pilot oil drain is impossible | ||||||||||||||||||
| Port Y | With external pilot oil drain bar | DC 210 AC 160 | ||||||||||||||||
| Min. control pressure | With external pilot oil supply ( not apply to C、Z、F、 | Spring-centering 3-position valve 13 | ||||||||||||||||
| Hydraulic-centering 3-position valve 18 | ||||||||||||||||||
| Spring-return 2-position valve 13 | ||||||||||||||||||
| Hydraulic-return 2-position valve 8 | ||||||||||||||||||
| With internal pilot oil supply ( apply to C、Z、F、 G、H、P、T、V) bar | When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V | |||||||||||||||||
| Max. control pressure bar | 250 | |||||||||||||||||
| Fluid | Mineral oil,Phosphate ester | |||||||||||||||||
| Fluid temperature range ℃ | -30 to +80 ( NBR seals | |||||||||||||||||
| -20 to +80 ( FKM seals ) | ||||||||||||||||||
| Switching pilot oil volume | ||||||||||||||||||
| - Spring-centering 3-position valve cm3 | 14.2 | |||||||||||||||||
| - 2-position valve cm3 | 28.4 | |||||||||||||||||
| Hydraulic-centering 3-position valve | ||||||||||||||||||
| - From"0"position to working position"a" cm3 | 7.15 | |||||||||||||||||
| - From working position"a" to "0"position cm3 | 7.0 | |||||||||||||||||
| -From "0"position to working position"b" cm3 | 14.15 | |||||||||||||||||
| -From working position"b" to "0"position cm3 | 5.73 | |||||||||||||||||
| * Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC) | ||||||||||||||||||
| Control pressure bar | 50 | 140 | 210 | 250 | ||||||||||||||
| AC | DC | AC | DC | AC | DC | AC | DC | |||||||||||
| - Spring-centering 3-position valve ms | 50 | 85 | 40 | 75 | 35 | 70 | 30 | 65 | ||||||||||
| - 2-position valve ms | 120 | 160 | 100 | 130 | 85 | 120 | 70 | 105 | ||||||||||
| - Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | a | b | a | b | ||
| 30 | 35 | 55 | 65 | 30 | 35 | 55 | 65 | 25 | 30 | 50 | 60 | 25 | 30 | 50 | 60 | |||
| *Switching times (= Valve switching time from the neutral position to the switched position) | ||||||||||||||||||
| - Spring-centering 3-position valve ms | 40 | |||||||||||||||||
| - 2-position valve ms | 120 | 125 | 95 | 100 | 85 | 90 | 75 | 80 | ||||||||||
| - Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | a | b | a | b | ||
| 20 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | |||
| Installation position | C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily | |||||||||||||||||
| Flow of shortest switching time L/min | about 35 | |||||||||||||||||
| Weight kg | about 18 | |||||||||||||||||
NG32
| Specifications | H-...WEH32... type | ...WEH32... type | ||||||||||||
| Max. operating pressure:P、A、B | 350 | 280 | ||||||||||||
| Port T | With external pilot oil drain bar | 250 | ||||||||||||
| With internal pilot oil drain bar | DC 210 AC 160 | |||||||||||||
| Hydraulic-centering 3-position valve With internal pilot oil drain is impossible | ||||||||||||||
| Port Y | With external pilot oil drain bar | DC 210 AC 160 | ||||||||||||
| Min. control pressure | With external pilot oil supply With internal pilot oil supply | 3-position valve 8.5 | ||||||||||||
| Spring-return 2-position valve 10 | ||||||||||||||
| Hydraulic-return 2-position valve 15 | ||||||||||||||
| With internal pilot oil supply ( apply to C、Z、F、 G、H、P、T、V) bar | When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V | |||||||||||||
| Max. control pressure bar | 250 | |||||||||||||
| Fluid | Mineral oil,Phosphate ester | |||||||||||||
| Fluid temperature range ℃ | -30 to +80 ( NBR seals | |||||||||||||
| -20 to +80 ( FKM seals ) | ||||||||||||||
| Viscosity range mm2/s | 2.8 to 500 | |||||||||||||
| Switching pilot oil volume | ||||||||||||||
| - Spring-centering 3-position valve cm3 | 29.4 | |||||||||||||
| - 2-position valve cm3 | 58.8 | |||||||||||||
| Hydraulic-centering 3-position valve | ||||||||||||||
| - From"0"position to working position"a" cm3 | 14.4 | |||||||||||||
| - From working position"a" to "0"position cm3 | 15.1 | |||||||||||||
| - From "0"position to working position"b" cm3 | 29.4 | |||||||||||||
| - From working position"b" to "0"position cm3 | 14.4 | |||||||||||||
| * Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC) | ||||||||||||||
| Control pressure bar | 50 | 150 | 250 | |||||||||||
| AC | DC | AC | DC | AC | DC | |||||||||
| - Spring-centering 3-position valve ms | 65 | 80 | 50 | 90 | 35 | 105 | ||||||||
| - 2-position valve ms | 100 | 130 | 75 | 100 | 60 | 115 | ||||||||
| - Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | ||
| 55 | 60 | 100 | 105 | 40 | 45 | 85 | 95 | 35 | 40 | 85 | 95 | |||
| *Switching times (= Valve switching time from the neutral position to the switched position) | ||||||||||||||
| - Spring-centering 3-position valve ms | ( DC :50,AC :60) | |||||||||||||
| - 2-position valve ms | 115 | 90 | 35 | 70 | 65 | 65 | ||||||||
| - Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | ||
| 30 | 50 | 30 | 40 | 60 | 75 | 30 | 30 | 105 | 140 | 50 | 50 | |||
| Installation position | C、D、K、Z、YType hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily | |||||||||||||
| Flow of shortest switching time L/min | about 50 | |||||||||||||
| Weight kg | about 36 | |||||||||||||

ADD: Address: No. 81, Zhuhang Road, Minhang District, Shanghai(Shanghai Lixin Hydraulics Co., Ltd.)
TEL: 021-31616718 Tel: 021-31616718, ext. 8000 ( reception )
© 2023 Shanghai Lixin Hydraulics Co., Ltd. copyright hu13042344