• Convert oil pressure signal into electric switch signal
| Weight | – Pressure switch | kg | 0.8 | |
| –Sandwich sub-plate mounting for vertical stacking assemblies | kg | 0.8 (NS 6, Sub-plate mounting height 40.5mm) | ||
| 3 (NS 6, Sub-plate mounting height 120mm) | ||||
| 2 (NS 10) | ||||
| Fluid | Mineral oil suitable for NBR and FKM seal | |||
| Phosphate ester for FKM seal | ||||
| Fluid temperature range | ℃ | -20 to +80(FKM seals) | ||
| –30 to +80(NBR seal) | ||||
| Viscosity range | mm2/s | 2.8 to 500 | ||
| Degree of contamination | Maximum permissible degree of fluid contamination: Class 9. NAS 1638 or 20/18/15, ISO4406 | |||
| Switching accuracy (repeatability) | <±1% of setting range | |||
| Permissible switching frequency | times/min | 80 | ||
| Pressure of setting range | ||||
| Pressure stage (Max. setting pressure ) (bar) | Max. operating pressure (bar) | Pressure of setting range (bar) | ||
| 50 | 350 | 2 to 50 | ||
| 100 | 350 | 4 to 100 | ||
| 200 | 350 | 5 to 200 | ||
| 350 | 500 | 8 to 350 | ||
| Electrical connection | plug-in connector to DIN 43 650,form A, 3-pin + PE | |||
| Max. connection cross sectional area | mm2 | 0.5 | ||
| Max. contact load | - AC | 250V/5A | ||
| - DC | 50V/1A;125V/0.03A;250V/0.02A | |||
| Protection to DIN 40 050 | IP65 | |||
| With DC inductive loading, a spark suppressor must be provided in order to increase the service life. | ||||